Located on the Meramec River, Fenton, Missouri is a small city with just over 4,000 people. While Fenton is home to gorgeous parks and the nearly century old Fenton Fire District , it also boasts a rich history dating back at least 900 years to early native settlements in the area. Since 1926, Classic Aire Care has been proud to be part of Fenton’s rich history, providing locals with quality home comfort services, including:
- Heating repair and heating system installation, maintenance, and replacement
- Air conditioning repair, installation, maintenance, and replacement
- Plumbing and drain services
- Air filtration system service
- Best air quality, insulation, and home energy services
- We are here to answer your call 24 hours a day, 7 days a week
- Plus many more!
Whether you need a plumber or the best heating and cooling services in or around Fenton, you can trust an experienced plumbing and HVAC contractor at Classic Aire Care for all your heating, cooling, and plumbing needs! We service any type of plumbing, heating or AC system, and we provide 24-hour emergency service.
To learn more about our services, contact Classic Aire Care at (314) 329-1943 today!
HVAC Repair in Fenton: Furnace Repair, AC Repair, & Much More
At Classic Aire Care, we have a dedicated team of HVAC experts who are NATE certified and armed with the latest tools and technology to help you solve your most difficult heating and cooling problems. We offer complete installation, replacement, repair, and maintenance services, as well as 24-emergency HVAC services for problems that happen after normal business hours.
We work with a variety of heating and cooling systems, including:
- Furnaces
- Boilers
- Heat pumps
- Central AC systems
- Ductless systems
- Packaged systems
- Rooftop AC units
- Air handlers
- And More!
From replacing a broken belt or changing an air filter to replacing an AC compressor or installing a new furnace, you can count on our team at Classic Aire Care for all your HVAC needs!
For more information about our HVAC services, contact us today! We serve the entire Fenton area, from Olde Towne Fenton to Yarnell Road, Bowles Avenue, and beyond!
Fenton Plumbing Services
Plumbing problems can be inconvenient, as well as costly, if they are not repaired quickly. At Classic Aire Care, we can handle all your plumbing and drain problems, from clogged toilets and sinks to broken sewer pipes. Our plumbing services include:
- Water, drain, and sewer pipe installation and repair
- Gas line installation and repair
- Drain cleaning and clog removal
- Sewer auguring and trenchless pipe repair
- Fixture installation and repair
- Faucet repair and replacement
- Water heater replacement and repair
- Leak detection and plumbing inspections
- And more!
Our professional plumbers are fully licensed, bonded, and insured, and they are available at any time for help to answer your call 24 hours a day, 7 days a week!
To learn more about our plumbing services, contact us today!
Home Energy &Â Air Quality Services in Fenton
Even with a quality HVAC system, you could be spending too much on your utility bills while experiencing sub-par comfort. At Classic Aire Care, we offer a variety of home energy services that can help you reduce your energy costs. We also provide indoor air quality services that can improve your comfort and your health. These services include:
- Whole-home energy audits and inspections
- Programmable thermostat installations
- Insulation and air sealing services
- Air purifier and air cleaner installations
- Humidity control system installation and maintenance
- Ventilation system installation and maintenance
- And much more!
To learn more about any of these services, contact us today!
Call Today for Home Comfort Services in Fenton, MO
With our prompt, reliable service and our team of talented professionals, you can trust Classic Aire Care to quickly and perfectly handle all your HVAC, plumbing, and home comfort needs, leaving you more time to enjoy a walk along the Meramec River or an evening at the Sunset Country Club!
For an appointment, contact Classic Aire Care at (314) 329-1943 today!
Other Cities We Serve
We serve cities throughout the St. Louis area including much of St. Louis, St. Charles, and Jefferson counties. Specific areas we serve include Creve Coeur, Olivette, Maryland Heights, St. Charles, University City, Chesterfield, Clayton, Town and Country, and Overland.
Recent Jobs and Reviews in Fenton, MO
Job Locations and Reviews
Completed warranty replacement of outdoor condensing unit, serial number 1926C38115. Installed new condenser, connected refrigerant lines and electrical service, verified proper system operation using digital manifold gauges, and confirmed appropriate pressures and temperatures. Unit mounted on pad with all penetrations properly sealed; defective unit retained per warranty requirements.
Responded to no-cool complaint on residential cooling system less than 10 years old. Upon arrival, confirmed unit was not maintaining set temperature as reported. Advised homeowner to turn off cooling unit and leave fan in auto position to prevent further strain on system. Inspected return air grille and documented significant dust and debris accumulation on louvers and surrounding areas, which was restricting proper airflow to the system. Restricted airflow can cause reduced cooling capacity, increased energy consumption, and potential compressor damage due to inadequate return air volume. Photographed conditions for documentation purposes. System requires filter replacement and thorough cleaning of return air pathways to restore proper airflow and cooling performance.
Responded to callback for cooling system blowing warm air on unit over 10 years old located in side yard. Upon arrival, performed diagnostic inspection of outdoor condenser unit and associated components. Identified operational issue affecting cooling capacity. Completed necessary repairs to restore proper system function and verified unit cycling correctly with adequate airflow through condenser coils. System tested and confirmed returning to normal cooling operation.
Replaced failed evaporator coil on residential air handler system installed in utility closet. Removed old coil, installed new replacement unit, reconnected refrigerant lines and electrical connections, and verified proper operation of heating and cooling functions. Disposed of defective coil per standard procedures.
Conducted comprehensive site assessment for standby generator installation. Evaluated existing electrical service panel containing multiple circuit breakers with main disconnect and documented current electrical infrastructure configuration. Assessed exterior foundation area and identified optimal generator placement location considering drainage conditions, foundation access, and utility clearances. Documented site conditions including moisture patterns near foundation and existing electrical service capacity. Prepared detailed estimate for complete automatic transfer switch installation, generator pad preparation, fuel line connection, and integration with existing electrical system. Evaluation included load calculation requirements and transfer switch specifications necessary for seamless emergency power transition.
Completed cooling maintenance tune-up on 16-year-old AC system. System was operational upon arrival and confirmed working properly throughout inspection. Observed significant dust and debris accumulation on HVAC components, ductwork, and metal framework within air handler unit, indicating extended operation without recent maintenance. Installed new 16x25x1 pleated air filter to restore proper airflow and system efficiency.
Responded to callback regarding inadequately cleaned filters and clogged evaporator coil on hallway unit. Upon inspection, found evaporator coil heavily contaminated with dust, dirt, debris, and hair buildup throughout aluminum fins, significantly restricting airflow. Coil showed extensive accumulation between fin spaces, particularly in center and lower sections, causing reduced system performance. Documented coil condition with photographs showing dark discoloration and blockage throughout heat exchanger assembly. Addressed customer concerns regarding maintenance quality and provided guidance on proper cleaning procedures for severely impacted coil assembly.
Responded to no cooling complaint on residential air conditioning system less than 10 years old located behind property. Upon arrival, performed diagnostic evaluation of outdoor condenser unit and system operation. Unit showed signs of normal outdoor environmental exposure with weathering on metal grilles and mesh panels. Inspected refrigerant line connections, electrical components, and overall system condition. Advised customer on proper thermostat operation and system settings to achieve desired temperature setpoint. System found to be operational with no mechanical failures identified. Provided guidance on unit maintenance and proper operation procedures.
Responded to no cooling complaint at mobile home with 7-year-old AC system. Upon arrival, confirmed unit was not providing adequate cooling to structure. Connected manifold gauge set to measure system pressures and diagnose refrigerant charge levels. Inspected condenser coil and found heavy dirt accumulation on fins restricting airflow. Evaluated system operating pressures against manufacturer specifications to determine root cause of cooling failure.
Completed cooling system tune-up on single Trane AC unit located on side of home. Performed comprehensive maintenance inspection, checked refrigerant levels, cleaned condenser coils, verified electrical connections, and tested system operation. Unit filter inspected and found in acceptable condition with minimal dust accumulation; all components functioning properly with no issues identified.
Completed comprehensive cooling maintenance tune-up on a 15-year-old residential air conditioning system. Performed standard preventive maintenance procedures including inspection of outdoor condenser unit, verification of proper airflow through louvered fins, assessment of component condition, and system operational testing. Unit was found to be functioning properly with no immediate repairs required; exterior housing showed typical weathering consistent with age but remained structurally sound with adequate airflow clearance maintained around the installation.
Replaced defective zone control panel, blower wheel, and outdoor disconnect to restore proper system operation. All failed components were removed and disposed of, with new parts installed and tested for proper function. System confirmed operational upon completion.
Responded to service call for downstairs zone unit where equipment tags had detached. Performed thorough inspection of air handling system and verified all components operating within normal parameters. Confirmed thermostat control, wiring connections, and mechanical components functioning properly with no issues detected.
Responded to no-cool call on 10+ year old outdoor unit located at side of home. Upon arrival, customer reported AC unit had been freezing up and was shut off. Connected Fieldpiece SMAN refrigerant manifold with micron gauge to system for diagnostic testing. Performed pressure and temperature readings on refrigerant circuit to identify cause of freeze-up condition. Measurements indicated abnormal operating pressures consistent with restricted airflow or low refrigerant charge. Documented system conditions with diagnostic equipment showing multiple temperature and pressure values for further analysis and repair recommendations.
Responded to no-cool call on 12-year-old outdoor unit with non-operational condenser fan. Upon arrival, confirmed condenser fan motor was inoperative and unit was overheating as reported. Diagnosed failed condenser fan motor and provided customer with repair options and pricing. Unit was already shut off per prior instructions to prevent compressor damage from inadequate heat dissipation.
Completed comprehensive electrical inspection of residential property focusing on exposed wiring systems in attic space and HVAC electrical connections. Inspected bundled yellow electrical cables and white communication wiring running along structural beams, verified proper mounting of junction boxes and cylindrical fixtures, and examined conduit installations. Evaluated internal electrical components of wall-mounted HVAC unit, including motor housing, control wiring, and connection integrity. All systems found to be properly installed and functioning within normal parameters.
Responded to no cooling complaint affecting entire residence. Upon arrival, performed system inspection and discovered severe frost and ice accumulation on refrigerant lines at indoor air handler unit. Heavy frost buildup observed on both suction line (large insulated pipe) and liquid line connections, indicating restricted airflow or low refrigerant charge causing evaporator coil to freeze. Inspected outdoor condensing unit and associated refrigerant piping. Found evidence of possible refrigerant leak or system restriction. Checked condensate drain line for proper operation. System was shut down to allow ice to thaw completely before further diagnostics could be performed. Advised customer that frozen evaporator coil must fully defrost before accurate system testing and diagnosis can occur. Recommended follow-up visit to check refrigerant charge levels, test airflow across evaporator coil, inspect air filter condition, and verify proper system operation once ice has melted. Took dia
Responded to no cooling complaint on residential split system air conditioning unit. Upon arrival, found outdoor condenser heavily obstructed by overgrown vegetation and ground cover, restricting proper airflow to unit. Cleared weeds, plants, and debris from around condenser cabinet to restore minimum clearance requirements for adequate air circulation. Verified unit operation after vegetation removal, restoring cooling function to system.
Replaced defective thermostatic expansion valve (TXV) on unit S/N 1524E72334 under full warranty coverage due to no cooling condition. Verified proper system operation using digital manifold gauges, confirming appropriate superheat and subcooling readings post-repair. Retained failed component per warranty requirements.
Returned to address ongoing system issue after previous control board replacement did not resolve the problem. Performed diagnostic evaluation on HVAC unit and inspected control board installation and wiring connections. Documented equipment condition with photos showing circuit board components, LED indicators, and wiring harness. Assessed system operation and identified that additional repairs are required beyond the control board replacement. Provided quote for necessary repairs to restore proper system function.