Call Today (314) 329-1943 Schedule Service

Reliable HVAC and Plumbing Services in Ellisville, MO

Water Heater Maintenance

Ellisville, MO, is a bustling suburban neighborhood located just to the west of St. Louis. Ellisville is a wonderful place to call home, boasting a welcoming atmosphere that feels just right for families. With its beautiful parks and a vibrant hub of local businesses, it’s a haven for residents and visitors alike. Whether you’re spending a lovely afternoon at Bluebird Park, wandering along the scenic Rock Hollow Trail, or checking out the Ellisville Farmers Market, there’s always an exciting activity waiting for you. Residents in Ellisville deserve a cozy home to come back to, particularly with the ever-changing weather in Missouri.

At Classic Aire Care, we take pride in offering exceptional HVAC and plumbing services in Ellisville, dedicated to keeping your home functioning and comfortable throughout the year, no matter the weather outside. When winter’s chill sets in and your furnace needs a little TLC, or when the summer sun blazes down and you find yourself in need of a new AC unit, our skilled technicians are on call.

We offer reliable furnace repair and furnace installation services in Ellisville, ensuring your home remains warm, safe, and energy-efficient all winter long. Whether you’re replacing an aging system or installing one in a new build, we’ve got you covered.

If you’re looking for reliable heating, cooling, and plumbing services in Ellisville, MO, don’t hesitate to reach out to us at (314) 329-1943 today! 

Our Core HVAC and Plumbing Solutions for the Residents of Ellisville

Expert AC and Furnace Installations 

Winters in Ellisville can be extremely cold and sometimes surprising, so it’s important to have a dependable furnace to keep your home cozy and warm. Similarly, summer days can become hot and humid, making it essential to have a reliable air conditioning system to ensure a cool atmosphere. 

Our passionate team of skilled technicians is here to provide you with top-notch furnace and AC installation services, making sure your home 

We offer a range of services to meet your heating and cooling installation needs:

  • New furnace installation to keep your family warm during freezing Missouri winters
  • New AC installation to ensure your home stays comfortable and efficient
  • Complete system replacements for outdated or malfunctioning units
  • Comprehensive system assessments to determine the best fit for your home
  • Guidance on energy-efficient options to help reduce costs and improve performance

Whether you’re upgrading an old system or installing a brand-new unit, our goal is to provide a seamless installation experience with minimal disruption to your home. We take the time to ensure your system is functioning at peak performance, giving you peace of mind and year-round comfort.

What’s more, our installation techniques are tailored to the unique needs of your home, keeping in mind that older homes may require a different approach and newer homes will have differing needs.

Scheduled and Flexible HVAC and Plumbing Maintenance

Staying on top of regular HVAC maintenance is crucial for preventing expensive repairs, enhancing energy efficiency, and extending the lifespan of your heating and cooling systems. Our committed team is here to offer you thorough maintenance services, ensuring that your equipment operates smoothly and efficiently all year round.

Here are some important advantages of keeping up with regular maintenance:

  • Reduces energy costs by improving efficiency
  • Helps avoid those surprise breakdowns and the costly repairs that come with them.
  • Helps your HVAC system last longer
  • Enhances the quality of the air inside your home

With our Planned Maintenance Agreement (PMA) program, homeowners in Ellisville enjoy the benefits of priority service, lower repair costs, and expert care for their systems, ensuring they run smoothly and providing peace of mind for years to come.

Thorough AC and Furnace Repair in Ellisville 

When your HVAC or plumbing system isn’t functioning as it should, it can truly throw a wrench in your daily routine. Our dedicated technicians are ready to assist you, providing quick and reliable repair services for everything from small problems to significant system breakdowns through partnering with top brands. 

If you’re experiencing issues like uneven heating, strange furnace noises, or a system that won’t start, our furnace and ac repair services in Ellisville are fast, reliable, and effective. We’ll diagnose the issue quickly and get your heat back on in no time.

We take you through our repair and replacement process, which involves:

  • A thorough evaluation of the current state of your system
  • Genuine and transparent suggestions for fixing or replacing HVAC systems
  • Affordable options designed just for you
  • Efficient and careful installations designed to save you money over the long haul

No matter what challenges arise, our committed team is here to make everything easier for you, helping you get back to the comfort of your home as swiftly as we can. Whether you need AC repair in Ellisville, or a brand new furnace replacement, we have you covered.

Why Choose Classic Aire Care for Your HVAC and Plumbing Needs in Ellisville?

We Prioritize Dedicated and Tailored Service 

Our commitment to experience, reliability, and a focus on our customers sets us apart. Classic Aire Care is proud to be the reliable partner for HVAC and plumbing services in Ellisville and its neighboring communities. We take pride in our strong reputation, which is founded on delivering high-quality workmanship, providing clear and honest service, and always putting our customers’ needs first.

Why choose us?

  • Skilled and NATE-certified technicians on call
  • Transparent pricing with no hidden surprises for AC repair near you
  • Our emergency services are here for you around the clock, every day of the week.
  • We offer a variety of financing options to ensure that our services remain affordable for everyone
  • Dedication to supporting and uplifting the local community

Whether it’s a small fix or a major system overhaul, our team is committed to delivering outstanding service that ensures your home remains cozy and inviting throughout the year.

Further, we know that emergencies happen at the most inconvenient of times, so rely on us for 24/7, dependable service.

Contact HVAC and Plumbing Professionals in Ellisville Today

Whenever you’re in need of AC repair in Ellisville, looking to upgrade your HVAC or plumbing system, or just wanting to keep things running smoothly with regular maintenance, Classic Aire Care’s skilled team is here to help every step of the way.

Give us a call at (314) 329-1943 or easily book an appointment online to discover the trusted heating, cooling, and plumbing services that Ellisville has to offer today!

Recent Jobs and Reviews in Ellisville, MO

Job Locations and Reviews

Completed comprehensive tune-up service on a 10-year-old ground-level AC condenser unit as part of Home Depot maintenance program. Performed thorough inspection of electrical control panel, verifying all relay contacts, integrated circuits, capacitors, and terminal block connections on the main control board; checked low-voltage control wiring and power conductor terminations for proper connections and signs of wear. Inspected and evaluated air filter condition, ensuring proper airflow through the system.
Completed comprehensive tune-up service on a 10-year-old ground-level AC condenser unit as part of Home Depot maintenance program. Performed thorough inspection of electrical control panel, verifying all relay contacts, integrated circuits, capacitors, and terminal block connections on the main control board; checked low-voltage control wiring and power conductor terminations for proper connections and signs of wear. Inspected and evaluated air filter condition, ensuring proper airflow through the system.
Drake K.
Drake K. Checked in
Completed comprehensive tune-up service on a 10-year-old ground-level AC condenser unit as part of Home Depot maintenance program. Performed thorough inspection of electrical control panel, verifying all relay contacts, integrated circuits, capacitors, and terminal block connections on the main control board; checked low-voltage control wiring and power conductor terminations for proper connections and signs of wear. Inspected and evaluated air filter condition, ensuring proper airflow through the system.
Ellisville, MO 63011
Responded to site for material retrieval from previous installation. Collected and removed remaining construction debris from basement, including PVC pipe sections, fittings, pipe insulation foam, and cardboard packaging materials left from prior service call. Materials documented photographically and removed from premises.
Responded to site for material retrieval from previous installation. Collected and removed remaining construction debris from basement, including PVC pipe sections, fittings, pipe insulation foam, and cardboard packaging materials left from prior service call. Materials documented photographically and removed from premises.
James W.
James W. Checked in
Responded to site for material retrieval from previous installation. Collected and removed remaining construction debris from basement, including PVC pipe sections, fittings, pipe insulation foam, and cardboard packaging materials left from prior service call. Materials documented photographically and removed from premises.
Ellisville, MO 63021
# HVAC Service - No Cool

Responded to service call for 13-year-old residential air conditioning system blowing warm air with no cooling capability. Upon arrival, verified thermostat was set to cooling mode at 90°F setpoint but system was not producing conditioned air. Proceeded to outdoor condenser unit for diagnostic inspection.

Opened electrical access panel on ground-level condenser unit and performed comprehensive visual and electrical assessment of internal components. Inspected capacitor, contactor, and associated wiring harnesses for signs of failure, damage, or degradation. Examined all wire connections, terminals, and safety devices for proper seating and continuity. Tested capacitor voltage and microfarad ratings to verify operational parameters were within manufacturer specifications.

Identified failed dual-run capacitor as root cause of no-cool condition. Component showed signs of bulging and tested significantly below rated capacitance values, preventing compressor and
# HVAC Service - No Cool

Responded to service call for 13-year-old residential air conditioning system blowing warm air with no cooling capability. Upon arrival, verified thermostat was set to cooling mode at 90°F setpoint but system was not producing conditioned air. Proceeded to outdoor condenser unit for diagnostic inspection.

Opened electrical access panel on ground-level condenser unit and performed comprehensive visual and electrical assessment of internal components. Inspected capacitor, contactor, and associated wiring harnesses for signs of failure, damage, or degradation. Examined all wire connections, terminals, and safety devices for proper seating and continuity. Tested capacitor voltage and microfarad ratings to verify operational parameters were within manufacturer specifications.

Identified failed dual-run capacitor as root cause of no-cool condition. Component showed signs of bulging and tested significantly below rated capacitance values, preventing compressor and
Vince D.
Vince D. Checked in
# HVAC Service - No Cool Responded to service call for 13-year-old residential air conditioning system blowing warm air with no cooling capability. Upon arrival, verified thermostat was set to cooling mode at 90°F setpoint but system was not producing conditioned air. Proceeded to outdoor condenser unit for diagnostic inspection. Opened electrical access panel on ground-level condenser unit and performed comprehensive visual and electrical assessment of internal components. Inspected capacitor, contactor, and associated wiring harnesses for signs of failure, damage, or degradation. Examined all wire connections, terminals, and safety devices for proper seating and continuity. Tested capacitor voltage and microfarad ratings to verify operational parameters were within manufacturer specifications. Identified failed dual-run capacitor as root cause of no-cool condition. Component showed signs of bulging and tested significantly below rated capacitance values, preventing compressor and
Ellisville, MO 63011
Completed comprehensive plumbing rough-in installation for basement bathroom renovation under permit. Relocated main water line pressure reducing valve and main shut-off valve from horizontal rafter installation to vertical riser configuration within 4" of wall, requiring removal of existing 3/4" flare x FIP connections, unsweating horizontal main, and installing new 3/4" copper 90-degree fitting with ball valve and PRV. Drilled three rafter penetrations for proper main line routing. Replaced front hose bibb and associated basement shut-off valve with new fixtures.

Installed new sump pump system with check valve and rerouted 1" discharge line, securing properly to wall structure for code compliance. Added two 3/4" tee fittings with ball valves on supply lines to service new basement bathroom fixtures. Performed complete shower drain reconfiguration by removing existing first-floor shower drain piping from base to tee connection, then repipe in 2" diameter with routing above rafter lin
Completed comprehensive plumbing rough-in installation for basement bathroom renovation under permit. Relocated main water line pressure reducing valve and main shut-off valve from horizontal rafter installation to vertical riser configuration within 4" of wall, requiring removal of existing 3/4" flare x FIP connections, unsweating horizontal main, and installing new 3/4" copper 90-degree fitting with ball valve and PRV. Drilled three rafter penetrations for proper main line routing. Replaced front hose bibb and associated basement shut-off valve with new fixtures.

Installed new sump pump system with check valve and rerouted 1" discharge line, securing properly to wall structure for code compliance. Added two 3/4" tee fittings with ball valves on supply lines to service new basement bathroom fixtures. Performed complete shower drain reconfiguration by removing existing first-floor shower drain piping from base to tee connection, then repipe in 2" diameter with routing above rafter lin
Bob S.
Bob S. Checked in
Completed comprehensive plumbing rough-in installation for basement bathroom renovation under permit. Relocated main water line pressure reducing valve and main shut-off valve from horizontal rafter installation to vertical riser configuration within 4" of wall, requiring removal of existing 3/4" flare x FIP connections, unsweating horizontal main, and installing new 3/4" copper 90-degree fitting with ball valve and PRV. Drilled three rafter penetrations for proper main line routing. Replaced front hose bibb and associated basement shut-off valve with new fixtures. Installed new sump pump system with check valve and rerouted 1" discharge line, securing properly to wall structure for code compliance. Added two 3/4" tee fittings with ball valves on supply lines to service new basement bathroom fixtures. Performed complete shower drain reconfiguration by removing existing first-floor shower drain piping from base to tee connection, then repipe in 2" diameter with routing above rafter lin
Ellisville, MO 63021
Completed installation of four sub-panels in residential property, mounting panels on interior walls with proper spacing and clearances per code requirements. Performed drywall modifications and patching around panel installations, with finish painting to integrate electrical infrastructure into living space.
Completed installation of four sub-panels in residential property, mounting panels on interior walls with proper spacing and clearances per code requirements. Performed drywall modifications and patching around panel installations, with finish painting to integrate electrical infrastructure into living space.
Kyle H.
Kyle H. Checked in
Completed installation of four sub-panels in residential property, mounting panels on interior walls with proper spacing and clearances per code requirements. Performed drywall modifications and patching around panel installations, with finish painting to integrate electrical infrastructure into living space.
Ellisville, MO 63011
Completed comprehensive electrical assessment of 75-year-old residential wiring system to provide estimate for full rewiring project including installation of proper grounding system and GFCI outlet protection throughout the property. Inspected existing exterior electrical service entrance, meter base, and conduit runs to evaluate current infrastructure and determine scope of work required to bring the electrical system up to current code standards for safety and functionality.
Completed comprehensive electrical assessment of 75-year-old residential wiring system to provide estimate for full rewiring project including installation of proper grounding system and GFCI outlet protection throughout the property. Inspected existing exterior electrical service entrance, meter base, and conduit runs to evaluate current infrastructure and determine scope of work required to bring the electrical system up to current code standards for safety and functionality.
Kyle H.
Kyle H. Checked in
Completed comprehensive electrical assessment of 75-year-old residential wiring system to provide estimate for full rewiring project including installation of proper grounding system and GFCI outlet protection throughout the property. Inspected existing exterior electrical service entrance, meter base, and conduit runs to evaluate current infrastructure and determine scope of work required to bring the electrical system up to current code standards for safety and functionality.
Ellisville, MO 63011
Completed seasonal cooling maintenance on two residential air conditioning systems (9-year-old unit and 15-year-old unit). Performed comprehensive tune-up procedures on both systems including inspection of evaporator coils, electrical connections, and control components. Verified proper operation of compressors, checked refrigerant levels, cleaned condenser coils, tested capacitors and contactors, inspected wiring and terminals for secure connections, and confirmed both systems are operating within manufacturer specifications. All safety controls tested and functioning correctly. Both units left in proper working condition with no deficiencies noted.
Completed seasonal cooling maintenance on two residential air conditioning systems (9-year-old unit and 15-year-old unit). Performed comprehensive tune-up procedures on both systems including inspection of evaporator coils, electrical connections, and control components. Verified proper operation of compressors, checked refrigerant levels, cleaned condenser coils, tested capacitors and contactors, inspected wiring and terminals for secure connections, and confirmed both systems are operating within manufacturer specifications. All safety controls tested and functioning correctly. Both units left in proper working condition with no deficiencies noted.
Mitchell L.
Mitchell L. Checked in
Completed seasonal cooling maintenance on two residential air conditioning systems (9-year-old unit and 15-year-old unit). Performed comprehensive tune-up procedures on both systems including inspection of evaporator coils, electrical connections, and control components. Verified proper operation of compressors, checked refrigerant levels, cleaned condenser coils, tested capacitors and contactors, inspected wiring and terminals for secure connections, and confirmed both systems are operating within manufacturer specifications. All safety controls tested and functioning correctly. Both units left in proper working condition with no deficiencies noted.
Ellisville, MO 63021
Completed cooling season tune-up maintenance on single outdoor AC unit paired with Carrier furnace system. Performed comprehensive inspection of all components, checked refrigerant levels, cleaned condenser coils, verified proper airflow through existing pleated filter and Aprilaire air purification system, and confirmed all electrical connections and controls operating within manufacturer specifications.
Completed cooling season tune-up maintenance on single outdoor AC unit paired with Carrier furnace system. Performed comprehensive inspection of all components, checked refrigerant levels, cleaned condenser coils, verified proper airflow through existing pleated filter and Aprilaire air purification system, and confirmed all electrical connections and controls operating within manufacturer specifications.
Alex M.
Alex M. Checked in
Completed cooling season tune-up maintenance on single outdoor AC unit paired with Carrier furnace system. Performed comprehensive inspection of all components, checked refrigerant levels, cleaned condenser coils, verified proper airflow through existing pleated filter and Aprilaire air purification system, and confirmed all electrical connections and controls operating within manufacturer specifications.
Ellisville, MO 63021
Ellisville, MO - Responded to no cooling complaint affecting entire residence. Upon arrival, found tripped breaker at electrical panel serving outdoor AC unit. Reset breaker and verified system restored to normal operation with proper cooling throughout home.
Justin W.
Justin W. Checked in
Responded to no cooling complaint affecting entire residence. Upon arrival, found tripped breaker at electrical panel serving outdoor AC unit. Reset breaker and verified system restored to normal operation with proper cooling throughout home.
Ellisville, MO 63021
Completed electrical estimate for multiple sub-panel installations at commercial facility. Assessed existing electrical infrastructure, including flush-mount residential-grade panel with multiple circuit breakers and Sylvania-branded panel with limited breaker occupancy. Documented panel configurations, measured dimensions, evaluated available capacity, and photographed current conditions to provide accurate material and labor requirements for proposed sub-panel additions.
Completed electrical estimate for multiple sub-panel installations at commercial facility. Assessed existing electrical infrastructure, including flush-mount residential-grade panel with multiple circuit breakers and Sylvania-branded panel with limited breaker occupancy. Documented panel configurations, measured dimensions, evaluated available capacity, and photographed current conditions to provide accurate material and labor requirements for proposed sub-panel additions.
David Y.
David Y. Checked in
Completed electrical estimate for multiple sub-panel installations at commercial facility. Assessed existing electrical infrastructure, including flush-mount residential-grade panel with multiple circuit breakers and Sylvania-branded panel with limited breaker occupancy. Documented panel configurations, measured dimensions, evaluated available capacity, and photographed current conditions to provide accurate material and labor requirements for proposed sub-panel additions.
Ellisville, MO 63011
Responded to no cooling complaint with indoor temperature reaching 80 degrees on a 9-year-old air conditioning system. Upon arrival, performed visual inspection of outdoor condenser unit, noting significant dirt and debris accumulation on heat exchanger coil with visible streaking and staining across horizontal fins, which was restricting proper airflow and heat transfer. Inspected indoor evaporator coil assembly in attic space, checking refrigerant line connections, filter drier, condensate drain, and electrical components. Cleaned condenser coil to remove built-up contamination and restore adequate airflow through heat exchanger. Verified proper refrigerant line connections and system operation. System restored to normal cooling capacity following coil cleaning and inspection.
Responded to no cooling complaint with indoor temperature reaching 80 degrees on a 9-year-old air conditioning system. Upon arrival, performed visual inspection of outdoor condenser unit, noting significant dirt and debris accumulation on heat exchanger coil with visible streaking and staining across horizontal fins, which was restricting proper airflow and heat transfer. Inspected indoor evaporator coil assembly in attic space, checking refrigerant line connections, filter drier, condensate drain, and electrical components. Cleaned condenser coil to remove built-up contamination and restore adequate airflow through heat exchanger. Verified proper refrigerant line connections and system operation. System restored to normal cooling capacity following coil cleaning and inspection.
Chris R.
Chris R. Checked in
Responded to no cooling complaint with indoor temperature reaching 80 degrees on a 9-year-old air conditioning system. Upon arrival, performed visual inspection of outdoor condenser unit, noting significant dirt and debris accumulation on heat exchanger coil with visible streaking and staining across horizontal fins, which was restricting proper airflow and heat transfer. Inspected indoor evaporator coil assembly in attic space, checking refrigerant line connections, filter drier, condensate drain, and electrical components. Cleaned condenser coil to remove built-up contamination and restore adequate airflow through heat exchanger. Verified proper refrigerant line connections and system operation. System restored to normal cooling capacity following coil cleaning and inspection.
Ellisville, MO 63011
Conducted on-site electrical assessment for installation of new 200-amp main service panel and 100-amp subpanel, along with five to six additional outlets in the garage. Evaluated existing exterior electrical infrastructure, including weathered meter housing showing significant rust and corrosion on mounting components and enclosure. Documented current service configuration, conduit routing, and utility connection points to develop comprehensive installation estimate for panel upgrades and garage circuit expansion.
Conducted on-site electrical assessment for installation of new 200-amp main service panel and 100-amp subpanel, along with five to six additional outlets in the garage. Evaluated existing exterior electrical infrastructure, including weathered meter housing showing significant rust and corrosion on mounting components and enclosure. Documented current service configuration, conduit routing, and utility connection points to develop comprehensive installation estimate for panel upgrades and garage circuit expansion.
Kyle H.
Kyle H. Checked in
Conducted on-site electrical assessment for installation of new 200-amp main service panel and 100-amp subpanel, along with five to six additional outlets in the garage. Evaluated existing exterior electrical infrastructure, including weathered meter housing showing significant rust and corrosion on mounting components and enclosure. Documented current service configuration, conduit routing, and utility connection points to develop comprehensive installation estimate for panel upgrades and garage circuit expansion.
Ellisville, MO 63011
Responded to no cooling complaint on 10+ year old ground-level condensing unit located in backyard. Upon arrival, found exterior unit heavily contaminated with accumulated dirt, dust, and debris on cabinet panels and condenser coil fins, significantly restricting airflow and heat transfer capability. Performed thorough cleaning of condenser coil and exterior surfaces to remove environmental buildup. Inspected indoor furnace unit and associated components including condensate drain system, gas line connections, and ductwork—all found in acceptable operating condition. Unit restored to proper cooling operation following maintenance procedures.
Responded to no cooling complaint on 10+ year old ground-level condensing unit located in backyard. Upon arrival, found exterior unit heavily contaminated with accumulated dirt, dust, and debris on cabinet panels and condenser coil fins, significantly restricting airflow and heat transfer capability. Performed thorough cleaning of condenser coil and exterior surfaces to remove environmental buildup. Inspected indoor furnace unit and associated components including condensate drain system, gas line connections, and ductwork—all found in acceptable operating condition. Unit restored to proper cooling operation following maintenance procedures.
Anthony L.
Anthony L. Checked in
Responded to no cooling complaint on 10+ year old ground-level condensing unit located in backyard. Upon arrival, found exterior unit heavily contaminated with accumulated dirt, dust, and debris on cabinet panels and condenser coil fins, significantly restricting airflow and heat transfer capability. Performed thorough cleaning of condenser coil and exterior surfaces to remove environmental buildup. Inspected indoor furnace unit and associated components including condensate drain system, gas line connections, and ductwork—all found in acceptable operating condition. Unit restored to proper cooling operation following maintenance procedures.
Ellisville, MO 63011
Responded to no-cooling complaint on one-year-old Lennox air conditioning unit. Upon inspection, discovered severe electrical corrosion on contactor terminals and connection points affecting unit operation. Cleaned corroded terminals, verified proper electrical connections on low-voltage control wiring and contactor assembly, and confirmed EasyStart device functionality. Tested system operation and restored cooling capacity. Documented equipment condition with photos for warranty reference.
Responded to no-cooling complaint on one-year-old Lennox air conditioning unit. Upon inspection, discovered severe electrical corrosion on contactor terminals and connection points affecting unit operation. Cleaned corroded terminals, verified proper electrical connections on low-voltage control wiring and contactor assembly, and confirmed EasyStart device functionality. Tested system operation and restored cooling capacity. Documented equipment condition with photos for warranty reference.
Joe V.
Joe V. Checked in
Responded to no-cooling complaint on one-year-old Lennox air conditioning unit. Upon inspection, discovered severe electrical corrosion on contactor terminals and connection points affecting unit operation. Cleaned corroded terminals, verified proper electrical connections on low-voltage control wiring and contactor assembly, and confirmed EasyStart device functionality. Tested system operation and restored cooling capacity. Documented equipment condition with photos for warranty reference.
Ellisville, MO 63011
Ellisville, MO - Responded to service call for reported breaker issues on ground-level AC unit. Upon arrival, performed electrical diagnostics using clamp meter to measure amperage draw on the system, recording 25.8 amps at the outdoor condensing unit. Verified proper electrical operation and system functionality, confirming unit is operating within normal parameters.
Joe V.
Joe V. Checked in
Responded to service call for reported breaker issues on ground-level AC unit. Upon arrival, performed electrical diagnostics using clamp meter to measure amperage draw on the system, recording 25.8 amps at the outdoor condensing unit. Verified proper electrical operation and system functionality, confirming unit is operating within normal parameters.
Ellisville, MO 63011
Responded to service call for water leaking from top of air conditioning unit located in basement. Upon inspection, found excessive condensation and water accumulation on evaporator coil assembly and drain pan components. Identified clogged condensate drain line as primary cause of overflow condition. Cleared obstruction from drain line, verified proper drainage flow, and tested system operation. Unit cooling properly with condensate now draining correctly through cleared line.
Responded to service call for water leaking from top of air conditioning unit located in basement. Upon inspection, found excessive condensation and water accumulation on evaporator coil assembly and drain pan components. Identified clogged condensate drain line as primary cause of overflow condition. Cleared obstruction from drain line, verified proper drainage flow, and tested system operation. Unit cooling properly with condensate now draining correctly through cleared line.
Anthony L.
Anthony L. Checked in
Responded to service call for water leaking from top of air conditioning unit located in basement. Upon inspection, found excessive condensation and water accumulation on evaporator coil assembly and drain pan components. Identified clogged condensate drain line as primary cause of overflow condition. Cleared obstruction from drain line, verified proper drainage flow, and tested system operation. Unit cooling properly with condensate now draining correctly through cleared line.
Ellisville, MO 63021
Replaced failed compressor on HVAC unit serial number 1924f06602 and installed new 30-amp fuse. Recovered refrigerant from system using recovery tank, removed defective compressor, and installed replacement unit from ladder access. Documented old and new compressor serial numbers per warranty requirements for 3-year labor coverage. System tested and operational upon completion.
Replaced failed compressor on HVAC unit serial number 1924f06602 and installed new 30-amp fuse. Recovered refrigerant from system using recovery tank, removed defective compressor, and installed replacement unit from ladder access. Documented old and new compressor serial numbers per warranty requirements for 3-year labor coverage. System tested and operational upon completion.
Anthony L.
Anthony L. Checked in
Replaced failed compressor on HVAC unit serial number 1924f06602 and installed new 30-amp fuse. Recovered refrigerant from system using recovery tank, removed defective compressor, and installed replacement unit from ladder access. Documented old and new compressor serial numbers per warranty requirements for 3-year labor coverage. System tested and operational upon completion.
Ellisville, MO 63021
Ellisville, MO - Responded to no cooling complaint on 10+ year old residential AC unit located on side of home. Upon arrival, found unit had been shut off by customer. Performed complete system diagnostic including electrical checks, refrigerant pressure testing, and condenser operation assessment. Identified issue preventing proper cooling operation and provided repair recommendations to restore system functionality.
Brandon F.
Brandon F. Checked in
Responded to no cooling complaint on 10+ year old residential AC unit located on side of home. Upon arrival, found unit had been shut off by customer. Performed complete system diagnostic including electrical checks, refrigerant pressure testing, and condenser operation assessment. Identified issue preventing proper cooling operation and provided repair recommendations to restore system functionality.
Ellisville, MO 63011
Completed comprehensive cooling system tune-up on single outdoor AC unit. Performed standard maintenance protocol including inspection of internal components, electrical connections, and control board assembly. Evaluated and documented condition of 16x20x1 pleated air filter showing moderate dust accumulation. All electrical wiring, compressor components, and system controls found to be in functional operating condition.
Completed comprehensive cooling system tune-up on single outdoor AC unit. Performed standard maintenance protocol including inspection of internal components, electrical connections, and control board assembly. Evaluated and documented condition of 16x20x1 pleated air filter showing moderate dust accumulation. All electrical wiring, compressor components, and system controls found to be in functional operating condition.
Eric C.
Eric C. Checked in
Completed comprehensive cooling system tune-up on single outdoor AC unit. Performed standard maintenance protocol including inspection of internal components, electrical connections, and control board assembly. Evaluated and documented condition of 16x20x1 pleated air filter showing moderate dust accumulation. All electrical wiring, compressor components, and system controls found to be in functional operating condition.
Ellisville, MO 63011
Completed comprehensive HVAC tune-up maintenance service for Home Depot work order. Performed system inspection, replaced air filter with new pleated media filter, and inspected heat exchanger coils which showed clean condition with no debris accumulation or corrosion present.
Completed comprehensive HVAC tune-up maintenance service for Home Depot work order. Performed system inspection, replaced air filter with new pleated media filter, and inspected heat exchanger coils which showed clean condition with no debris accumulation or corrosion present.
Mitchell L.
Mitchell L. Checked in
Completed comprehensive HVAC tune-up maintenance service for Home Depot work order. Performed system inspection, replaced air filter with new pleated media filter, and inspected heat exchanger coils which showed clean condition with no debris accumulation or corrosion present.
Ellisville, MO 63021

Get An Instant Online Quote

Answer 4 easy questions and get a free onscreen quote on a new furnace and A/C or water heater

request quote
Review Image
our reviews

See What Your Neighbors Are Saying

Top notch install quality. While my ac wasn’t that old, I opted for a higher efficiency heat pump system and replace my worn-out older furnace! The difference in my home is night and day difference, can’t wait to see what the bills do.

Sean K.

Sean K.

Great customer service! Called for an emergency with my furnace after hours (in the middle of winter), a mishap happened with their system. The manager Joe called me immediately in the morning, discounted my service and got Jack out in an hour. Diagnosed and fixed same…

Ebony K.

Ebony K.

I have my furnace and air conditioning system on a maintenance agreement with Classic Aire Care to be checked twice a year. They have been doing this since the system was installed eight years ago. They do excellent work and technicians are quality people. I would…

Gerald B.

Gerald B.

We enjoy the promptness and professionalism of every person we have met, encountered or had enter our home. They are very clean, neat and down-to-business kind of employees. Couldn't ask for more.

Cindy K.

Cindy K.

The Professionalism of this company as well our service technician Greg was more than just five-star rating. He took the time explained everything that he did and now my unit is running at tiptop shape.

Charles P.

Charles P.

What To Expect

Discover the Difference

100% Satisfaction Guaranteed

Over 100 Vans on The Road, Ready to Offer Same-Day Service

Over 3,000 5-Star Reviews

Free Estimates

Highly Trained Techs With Over 35 Years Of Experience

Commitment to Community

100% Satisfaction Guaranteed

Over 100 Vans on The Road, Ready to Offer Same-Day Service

Over 3,000 5-Star Reviews

Free Estimates

Highly Trained Techs With Over 35 Years Of Experience

Commitment to Community

Truck Image
Join the Classic Aire Care Membership Program

Save on Service & Enjoy Peace of Mind

  • Priority customer status
  • Discounts on repair services
  • Comprehensive maintenance & tune-ups
  • No overtime charges
  • Extended equipment life

Â